496372 Issue 1 9 of 34
4660/75
Refer to the appropriate installation manual.
Final Commissioning
After coding, switch on the battery. Find switch 2 of the small black 2-way DIL
switch (marked ON/OFF). Set to ON using a terminal screwdriver or ball
point pen. If your unit shows low battery operate the orange buttons five or six
times at five second intervals. The sixth and subsequent transmissions
should give a normal transmission.
Note: DIL switch changes will not take effect until the transmitter is operated twice.
Refit the lid and screws, and tighten them.
Testing
Determine the limits of the transmitter’s range and inform the user of these
limits. Check that the unit will function in all areas where the user EXPECTS
it to function and point out any discrepancies.
You can switch the 4602-55 on so that it transmits a continuous test signal.
This facility helps in range-testing and fault-finding. To activate the test signal
turn the switch marked TEST (on the 2-way DIL switch) to ON.
Figure 5. ON/OFF and Test Switches
To ensure good reception use the Scantronic 4690 field strength meter to
obtain accurate field strength readings and audible and visual indication of
the transmitter’s performance and any interference present.
Turn the TEST switch OFF when you have completed testing, or the trans-
mitter will block ALL radio signals to your receiver!
4603
Introduction
The 4603-60 is a programmable, self contained, multi-function transmitter.
The 4603-60 has a built in battery with up to five years life time and can be
fitted with a range of aerials.