Scantronic 4603 Manual de instalación Pagina 30

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 34
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 29
30 of 34 496372 Issue 1
4612
Switches 1 to 10 on the receiver match switches 1 to 8 and 1 to 2 on the
4609. Switch 3 on the 4609 matches switch 3 or 1 on the receiver depending
on if it is channel A or B. Jumper J2 matches switch 4 or 2 on the receiver
depending on if it is channel A or B. If J2 is linked then make sure switch is
on. If J2 is unlinked then make sure switch is off.
Figure 22. Coding 4609 for 4612
4611/3
Switches 1 to 8 and 1 to 3 on the receiver match switches 1 to 8 and 1 to 3
on the 4609. Switch 12 on the receiver corresponds to jumper J2 on the
4609. If switch 12 on the receiver is ON then place jumper J2 on the 4609
ON.
4660/75
Refer to installation manual.
Testing
To test if the smoke detector is working press the test button on the unit for
10 seconds. After 10 seconds the unit gives a tone and a transmission.
4624
Introduction
The 4624, 4-Channel Static Transmitter is a long-range telemetry transmitter
which can be used with two normally open and two normally closed inputs or
four normally closed inputs. The transmitter is powered from a 12VDC power
source and incorporates a constant input power monitoring circuit and low
battery indication, and is housed in an aluminium case.
4624
Vista de pagina 29
1 2 ... 25 26 27 28 29 30 31 32 33 34

Comentarios a estos manuales