496372 Issue 1 13 of 34
Mode 3 - Boat/caravan Single Zone Alarm Panel
In this mode the 4603-60 can be used as a boat or caravan single zone
alarm panel, which transmits alarm conditions to a remote on-site monitoring
centre.
Place Mode 1 switch ON, Mode 0 switch OFF.
Connect normally closed sensing device between A and Gnd (for example a
movement sensor).
Connect normally closed tamper loop between B and +Ve.
Connect arming switch (key switch or similar) between I/P Con and +Ve.
Figure 8. 4603 Boat Caravan Mode
The 4603-60 is disarmed with the keyswitch ON. While disarmed the unit
monitors input B continuously (24 hour tamper zone) and ignores input A. If
contact B opens the 4603-60 sends a transmission channel B.
The 4603-60 is armed when the keyswitch is OFF. When the switch opens
the 4603-60 sounds the beeper for a fixed 25 second exit period. At the end
of this period the 4603-60 monitors both inputs A and B. If input A opens the
4603-60 sounds the beeper for the 25 second entry period. Unless the unit is
disarmed by closing the keyswitch during the entry period the 4603-60 then
sends a transmission channel A. At the end of the transmission the 4603-60
re-arms input A.
The 4603-60 can be disarmed at any time by closing the keyswitch.
Coding the Transmitter
Set the radio site code (bank of 8 plus 4 DIP switches) as shown for the
4604. Do not use the las two switches in the bank of 4.
Mode 4 - Alarm/Tamper Transmission, With Restore On
Both Channels (Door Contact)
Place Mode 1 switch ON, Mode 0 switch OFF.
Connect a normally closed sensing loop between A and Gnd.
Connect a normally closed tamper loop between B and +Ve.
Link I/P Con to Gnd.