18 of 34 496372 Issue 1
Technical Specification
Dimensions h x w x d 102 x 44 x 20mm.
Input supply: 3.7V Lithium battery.
Temperature -10°C to 55°C. Humidity up to 80% (non
condensing).
Frequency 173.225 MHz.
Output power 1mW
Fully DTI approved to MPT1344 for alarm use only. No licence required.
BS6799 Classes 1-3.
Coding The Transmitter
Remove the self-tapping screws and carefully ease the top of the case
upwards.
Set the site code on the large 10-way DIL switch. Note that UP is ON and
DOWN is OFF. Do not set all switches to ON or the transmitter will not work
correctly.
4600
Set switches 1 to 6 to the site-code of the 4600. Set switches 7-10 as shown
below. The top button will set or unset the panel. The personal attack buttons
will trip zone 10 (as Personal Attack).
Figure 13. Coding for 4600
4618/9
Set switches 1 to 7 to the site code of the 4618/9. Set switches 8 to 10 to the
zone number. The top button triggers channel A. The side buttons trigger
channel B. For further information refer to the 4618 Installation Guide.
4605