16 of 34 496372 Issue 1
4618/9
Set switches 1 to 8 to the site code of the 4618/9. Set switches 9 to 10 to the
device number. The alarm channel triggers odd numbered zones. The
tamper channel triggers even number zones. For further information refer to
the 4618 Installation Guide.
Figure 11. Coding for 4618/9 modes 9-13 and 19
4611/4613
Not compatible.
4612
Set switches 1-10 to the site code of the 4612. The tamper channel triggers
channel B. The alarm channel triggers channel A.The 4612 must be in 2-
channel mode. For further information refer to the 4612 Installation Guide.
4660/75
Refer to the appropriate installation manual.
Switching On
After coding switch on the battery. Find switch 2 of the small black 2-way DIL
switch (marked BATT). Set to ON using a terminal screwdriver or ball point
pen. The transmission LED lights and the unit transmits an open tamper
alarm as the case is open. If your unit shows low battery operate back
tamper switch five or six times at five second intervals. The sixth and subse-
quent transmissions should give a normal transmission.
4604