12 of 34 496372 Issue 1
Technical Specification
This section summarises the overall capacities of the 4603-6x series.
Dimensions h x w x d 152 x 104 x 30mm.
Input supply Lithium battery.
Battery life Up to 5 years.
Lid tamper switch 24VDC @ 100mA.
Temperature -10°C to 55°C. Humidity up to 80% (non
condensing).
Power output 1mW.
Aerial BNC 50 Ohm impedance.
Frequency 4603UK-60 173.225 MHz.
Fully DTI approved to MPT1344 for alarm use only. No licence required.
BS6799 Class 2.
Programming
General
Mode Application
1 Single channel transmitter using Normally Open non-latching input.
This mode can be used for personal attack or call buttons.
3 Boat/Caravan single zone alarm panel.
4 Two channel transmitter using Normally Closed inputs. This mode
provides conventional alarm and tamper channels, both with
restore signal.
Mode 1 - Single Channel ‘A Trigger’ (PA Trigger)
Place Mode 0 and Mode 1 switches ON.
Connect a normally open switch from A to Gnd.
Leave inputs B and I/P Con disconnected.
Figure 7. 4603 Mode 1
When A is connected to Gnd, the unit transmits. The unit does not transmit
when the connection opens.
Coding the Transmitter
Set the radio site code (bank of 8 plus 4 DIP switches) as shown for the
4601.
4603