6 of 34 496372 Issue 1
Re-assembly
Refit the lid of the case, ensuring that the aerial cord is firmly gripped in the
guides provided and that the sealing “O” ring is correctly seated. Replace the
cross-headed screws into the holes and firmly screw the case together. It is
essential that the screws are tightly secured as the water-resistance is
dependant on this. If necessary, re-seal the aerial Entry/Exit point, with
DOW-CORNING sealant REF: RTV 3145.
ON NO ACCOUNT USE AN ACETIC-ACID BASED SEALANT. (Acetic acid
sealants have a vinegar-like smell).
CAUTION: After accidental immersion in any liquids, the unit should be
opened (as described above), the transmitter board removed
and the whole unit allowed to dry. When completely dry the
unit should be re-assembled, the case re-sealed (as described
in the previous paragraph) and the whole unit tested for correct
operation and range.
If the unit accidentally drops into non-liquid food substances, it
can be carefully wiped clean with a damp cloth. Under no
circumstances should it be washed under running water or
immersed in water or a cleaning fluid.
4602
Introduction
The 4602-55 can be used as a personal attack transmitter to provide remote
protection.
To operate, press the two orange side buttons together. The transmitter does
not signal if you press only one button. Note the black button fitted below the
left-hand orange button. This is a safety lock to prevent false activations.
Slide the black button upwards to lock the orange button.
Technical Specification
Dimensions (body) h x w x d 102 x 44 x 20mm.
Input supply 3.7V Lithium battery.
Frequency 173.225 MHz.
Output power 1mW.
Operating temperature -10° to +55°C. Humidity up to 80% (non
condensing).
Fully DTI approved to MPT1344. No licence required. For use in
BS6799:1986 systems classes 1-3.
4602
Comentarios a estos manuales